SECURITY SYSTEM INSTRUCTIONS
DSC-1550



1. ARMING ERROR


An error tone will sound if the system is unable to arm. This will happen in the system is not ready to arm, (a door is open or movement in front of a motion detector) or if an incorrect user code has been entered. If this happens press the (#) and try again.


NOTE: Any time you press the * and any other number you will need to press the # to return to normal operation. Also if an error is made when entering your code press the # to clear it out and return to normal. If the keypad is beeping press the # to silence.


2. BYPASS


To bypass any zone press *1 then the two digit zone number then #.

(example: *1 01 #, to bypass zone 1)

The bypass indicator should remain on. After you arm and disarm the system the bypass will clear.


3. CHIME


Press and hold the CHIME button on the right to turn the CHIME feature ON and OFF.


4. CODES


Press * then 5, then your master code, then the two digit number of the user number that you wish to add or change.  Then enter the new 4 digit code. (example:  *5 - master code - user number (2-6) - new code - #)

There are 6 user codes available and the master code is in position 1.  To change the master code press *5 current code, then 1, then the new code and #.   (example: *5 - master code - 01- new code - #)

To erase a code press *5, enter the master code, enter the user number you wish to delete, press the (****), 4 times and then press #.


5. DISARMING ERROR


If you enter an incorrect code the system will not disarm, press the (#) and enter the correct code.


4. FALSE ALARM


If the alarm was accidental, enter your Access Code to silence the alarm, then call your monitoring station to avoid a dispatch.


5. INSTANT ARM


Press * then 9 and enter your code to arm the system without any entry delay time.

NOTE: This has no effect on the exit time delay. (When using the *9 Instant arm you will still have whatever exit time to leave, but there will not be any entry time delay.)


6. MEMORY


When an alarm occurs the Memory indicator will turn on, To view which zone caused the alarm press the * then 3. When finished press # to return to normal.


7. SMOKE DETECTOR RESET


Press and hold the RESET button on the right.


8. TROUBLE


When a trouble condition is detected the Trouble indicator will turn on and the keypad will beep every 10 seconds. Press the # to silence the beeps. Press the * then 2 in order to view the trouble condition, each zone indicates a different problem. Below are the trouble conditions by number which they will appear on the touch pad.

NOTE:  When viewing the trouble condition on an LED touch pad the zone lights will light up to indicate the trouble.  If you are viewing the trouble on an LCD touch pad the trouble will read out on the screen.

 ZONE LIGHT
TROUBLE CONDITION
 WHAT TO DO
1LOW BATTERY
Call for service or replace the back up battery in the main control box.
2AC POWER FAILURE
Check to see if your transformer is plugged in.  Check your fuse box or circuit breakers for a popped fuse.  Call for service if trouble does not clear.
3FUSE TROUBLE
Call for service.
4FAILURE TO COMMUNICATE
This trouble will be cleared if the system tries to call the monitoring station again and is able to complete the call. If this trouble does not clean itself automatically, call for service.
5
FIRE CIRCUIT TROUBLE
Call for service.
6
LOSS OF TIME IN  THE SYSTEM CLOCK
See User Functions/ Time and Date


Press # to return to normal


9. USER FUNCTIONS/TIME AND DATE


(example: *6 - master code - 1 - HH-MM-MM-DD-YY - #)

Press the * then 6, enter the master code, press 1 then the time; HOURS, MINUTES, MONTH, DAY and YEAR. Then #. Time should be entered in Military format. EXAMPLE: *6 master code -1-10-05-03-01-06 - # (10:05 am March 01, 2006) for 10:05 PM enter 22-05-03-01-06)

**If you have the LCD touch pad, press the * then 6, enter your master code then use the < > to TIME AND DATE. Press * to select then change the time. Press # to return to normal.